Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Type of study
Language
Year range
1.
Chinese Journal of Radiation Oncology ; (6): 124-130, 2023.
Article in Chinese | WPRIM | ID: wpr-993162

ABSTRACT

Objective:To analyze the clinically acceptable and reproducible bladder and rectum volumes of prostate cancer patients during radiotherapy under bladder and bowel preparation, aiming to provide quantitative indicators for bowel and bladder preparation before and after radiotherapy.Methods:Clinical data of 275 prostate cancer patients with strict bladder and bowel preparation and completion of whole course radical radiotherapy at Sun Yat-sen University Cancer Center from April 2015 to December 2020 were retrospectively analyzed. Patients were scanned with cone beam CT (CBCT) before each treatment and the setup error was recorded. Sixty-six patients were selected by simple random sampling and the bladder and rectum on daily CBCT was outlined using MIM software. The relationship between the ratio of daily bladder or rectum volume to the planned bladder or rectum volume (relative value of volume) and setup error was analyzed. Quantitative data were expressed as mean±SD. Normally distributed data were analyzed by paired t-test while non-normally distributed data were assessed by Kruskal-Wallis test.Results:The bladder and rectum volume on planning CT were (370.87±110.04) ml and (59.94±25.07) ml of 275 patients. The bladder and rectum volumes on planning CT were (357.51±107.38) ml and (65.28±35.37) ml respectively of the 66 selected patients with 1611 sets of CBCT images. And the bladder and rectum volumes on daily CBCT were (258.96±120.23) ml and (59.95 ± 30.40) ml. The bladder volume of patients was decreased by 3.59 ml per day on average during the treatment and 0.37 ml for the rectum volume. According to the bladder volume on planning CT, all patients were divided into three groups: <250 ml, 250-450 ml and >450 ml groups. The relative value of volume in the 250-450 ml group during the course of radiotherapy was the smallest. And the setup error in the superior and inferior (SI) direction was (0.28±0.24) cm and (0.19±0.17) cm in the left and right (LR) direction, significantly lower than those in the other two groups (both P≤0.027). According to the rectum volume on planning CT, all patients were divided into four groups: <50 ml, 50-<80 ml, 80-120 ml and >120 ml groups. The <50 ml group had the smallest relative value of volume during radiotherapy, and the setup error in the SI direction was (0.26±0.22) cm and (0.24±0.22) cm in the anterior and posterior (AP) direction, significantly smaller than those in the other groups (both P≤0.003). The setup errors in the SI, LR, AP directions of the enrolled 66 patients were (0.30±0.25) cm, (0.20±0.18) cm and (0.28±0.27) cm, respectively. Among them, the relative value of bladder volume in the AP direction was (0.73±0.37) in the setup error <0.3 cm group, which was statistically different from those in the setup error 0.3-0.5 cm and >0.5 cm groups (both P<0.05). Conclusion:Under the bladder and bowel preparation before planning CT, the appropriate bladder and rectum volumes are in the range of 250-450 ml and <50 ml, which yields higher reproducibility and smaller setup error.

2.
Chinese Journal of Medical Education Research ; (12): 961-967, 2023.
Article in Chinese | WPRIM | ID: wpr-991449

ABSTRACT

This study summarizes related studies on readiness for online teaching in China and globally and constructs an online teaching readiness scale for higher education teachers with reference to related studies on online teaching competency, blended teaching readiness, and influencing factors for online teaching. This scale includes five dimensions, i.e., belief, teaching readiness, technical readiness, online communication readiness, and institutional support. A questionnaire survey and statistical analyses were performed to investigate the rationality of the scale, and then the scale was modified. The results show that the indicators of the scale have a good degree of fitting, and this study provides a necessary standard for examining the online teaching readiness of higher education teachers and new ideas for online teaching in colleges and universities.

3.
Chinese Journal of Medical Education Research ; (12): 481-485, 2023.
Article in Chinese | WPRIM | ID: wpr-991345

ABSTRACT

The medical massive open online course (MOOC) quality certification standard is the reference for the implementation of medical MOOC quality monitoring. This thesis utilizes data mining, quantitative analysis, qualitative analysis and other methods, taking the comment text of the Chinese medicine courses on the Ai Course (MOOC of China Universities) platform as the data source out of which to extract certain potential indicators for the medical MOOC quality certification standard. Based on the analysis of the existing research results on MOOC quality evaluation domestic and abroad as well as the relevant policies of the Ministry of Education, a medical MOOC quality accreditation standard including 6 first-level indicators are formed, including course content, teaching design and so on. Expert scores and AHP method were used to calculate the weight coefficient of the quality certification standard. Finally, this paper explains the procedure of medical MOOC quality certification in college. This certification system can be used to conduct self-assessment and quality monitoring of medical MOOC in colleges and universities.

4.
Journal of Southern Medical University ; (12): 1035-1040, 2023.
Article in Chinese | WPRIM | ID: wpr-987019

ABSTRACT

OBJECTIVE@#To identify the problems in clinical radiotherapy planning for cervical cancer through quantitative evaluation of the radiotherapy plans to improve the quality of the plans and the radiotherapy process.@*METHODS@#We selected the clinically approved and administered radiotherapy plans for 227 cervical cancer patients undergoing external radiotherapy at Sun Yat-sen University Cancer Center from May, 2019 to January, 2022. These plans were transferred from the treatment planning system to the Plan IQTM workstation. The plan quality metrics were determined based on the guidelines of ICRU83 report, the GEC-ESTRO Working Group, and the clinical requirements of our center and were approved by a senior clinician. The problems in the radiotherapy plans were summarized and documented, and those with low scores were re-planned and the differences were analyzed.@*RESULTS@#We identified several problems in the 277 plans by quantitative evaluation. Inappropriate target volume selection (with scores < 60) in terms of GTV, PGTV (CI) and PGTV (V66 Gy) was found in 10.6%, 65.2%, and 1% of the plans, respectively; and the PGTV (CI), GTV, and PCTV (D98%, HI) had a score of 0 in 0.4%, 10.1%, 0.4%, 0.4% of the plans, respectively. The problems in the organs at risk (OARs) involved mainly the intestines (the rectum, small intestine, and colon), found in 20.7% of the plans, and in occasional cases, the rectum, small intestine, colon, kidney, and the femoral head had a score of 0. Senior planners showed significantly better performance than junior planners in PGTV (V60 Gy, D98%), PCTV (CI), and CTV (D98%) (P≤0.046) especially in terms of spinal cord and small intestine protection (P≤0.034). The bowel (the rectum, small intestine and colon) dose was significantly lower in the prone plans than supine plans (P < 0.05), and targets coverage all met clinical requirements. Twenty radiotherapy plans with low scores were selected for re-planning. The re-planned plans had significantly higher GTV (Dmin) and PTV (V45 Gy, D98%) (P < 0.05) with significantly reduced doses of the small intestines (V40 Gy vs V30 Gy), the colon (V40 Gy vs V30 Gy), and the bladder (D35%) (P < 0.05).@*CONCLUSION@#Quantitative evaluation of the radiotherapy plans can not only improve the quality of radiotherapy plan, but also facilitate risk management of the radiotherapy process.


Subject(s)
Humans , Female , Uterine Cervical Neoplasms/radiotherapy , Rectum , Colon , Kidney , Organs at Risk
5.
Chinese Journal of Medical Education Research ; (12): 175-178, 2021.
Article in Chinese | WPRIM | ID: wpr-883575

ABSTRACT

Objective:To explore the learning experience of the medical massive open online course (MOOC) teaching design standard system constructed by the research group in the early stage.Methods:In this study, the questionnaire was adapted from four dimensions: academic analysis, curriculum content design, teaching process design, and teaching evaluation design, including 519 students majoring in clinical medicine of a university who had studied MOOC cases like "Ultra-early Diagnosis and Treatment of Acute Cerebral Infarction" based on the system. SPSS 25.0 was used for statistical analysis.Results:The system had a high degree of recognition in all dimensions, with 64.5% of academic analysis, 57.6% of content design, 54.5% of teaching design process, and 59.3% of teaching evaluation design.Conclusion:The study has found that the medical MOOC teaching design system has good learning experience effect. According to the data feedback, the key teaching design points such as the core factors of learning experience analysis and the suitability of teaching content in the practical operation of teaching design has been explored, providing the practical basis and method reference for the design of medical MOOC teaching design.

6.
Journal of Medical Postgraduates ; (12): 1160-1163, 2014.
Article in Chinese | WPRIM | ID: wpr-459654

ABSTRACT

[Abstract ] Objective Modern pharmacological studies confirmed Zhigancao Decoction total extract, single active ingredients and their combinations could obviously inhibit arrhythmia.This study was to investigate the effects of Zhigancao Decoction medicated serum combined with myocardial tissue/silicon substrate microelectrode arrays (MEA) on rapid atrial pacing(RAP). Methods New Zealand white rabbits were randomly divided into normal control group, normal serum control group, Zhigancao Decoction medica-ted serum group and water decoction group, 8 in each group.After the establishment of an atrial fibrillation rabbit model, the field ac-tion potential duration ( fAPD) of the right atrial appendage ( RAA ) tissue was measured and the effections of Zhigancao Decoction medicated serum and water decoction on the fAPD of RAA were observed. Results The successful modeling of rapid atrial pacing induced atrial fibrillation in rabbits contributed to the significant shortening of fAPD 12 h after pacing compared to that before pacing ([174.30 ±1.36]ms vs[162.48 ±0.88]ms, P<0.05).After giving 10%~25% Zhigancao Decoction medicated serum and water decoction, the fAPDs of RAA tissue in rabbits with atrial fibrillation were prolonged, which represented positive dose-response relation-ship.The fAPDs of the rabbits given serum containing 10%, 15%, 20%and 25%Zhigancao Decoction were respectively (170.81 ± 0.61)ms, (171.00 ±0.46)ms, (179.08 ±0.67)ms, (179.76 ±2.26)ms, which were longer than those of water decoction group ([163.82 ±0.780]ms, [163.66 ±0.95]ms, [174.06 ±1.32]ms, [176.84 ±1.19]ms), and the difference was statistically sig-nificant (P<0.05). Conclusion The fAPD can be taken as one index of cardiac electrophysiological change, and 10%~25%Zh-igancao Decoction medicated serum can lead to fAPD extension in rabbit model of atrial fibrillation, which might be the electrophysio-logical mechanism of anti-atrial fibrillation.

7.
Chinese Circulation Journal ; (12): 639-642, 2014.
Article in Chinese | WPRIM | ID: wpr-456365

ABSTRACT

Objective:To evaluate and screen the anti-atrial ifbrillation drug with multiion channel targets by micro-electrode chip technology in a rapid atrial pacing (RAP) rabbit model. Methods:A total of 32 rabbits were randomly divided into 4 groups, n=8 in each group. Potassium channel blocker (TEA) group, Potassium channel blocker (BaCl2) group, Potassium channel blocker (CdCl2) group and Amiodarone group. The electrode was inserted into right atrium via internal jugular vein with rapid right atrial pacing (600 beat/min) and the effect of each anti-atrial ifbrillation drug on ifeld action potential (fAPD) were measured in different groups. Results:With 24 hour RAP, the fAPD was prolonged from (176.67 ± 8.66) ms to (196.11 ± 10.76) ms, P=0.012 in TEA group;from (182.22 ± 12.87) ms to (191.11 ± 13.09) ms, P=0.039 in BaCl2 group;from (178.33±7.85) ms to (206.67 ± 9.70) ms, P=0.0015 in CdCl2 group;from (167.38 ± 13.67) ms to (185 ± 15.14) ms, P=0.002 in Amiodarone group. Conclusion: RAP induced atrial fibrillation in experimental rabbit model is a simple and feasible method for screening the anti-atrial fibrillation drugs, combining with micro-electrode chip technology, it might be used for developing the new product.

SELECTION OF CITATIONS
SEARCH DETAIL